Load Cell for Brugger HSG Series

‘


Request Quote

Please select a valid form

Description

Load Cell for Brugger HSG Series

This HSG-C/CC accessory allows you to adjust the sealing pressure at regular intervals. The whole procedure, from attachment to adjustment, takes only a few minutes.

Highlights

  • Adjustment of sealing force
  • Calibrated load cell
  • Easy to use
  • Adjustment on site

Adjusting the Force Display

The sealing force is set using an electronic pressure controller. To compensate for tolerances of the pressure controller, pneumatic cylinder, press head, and return springs, the control system calculates the characteristic curve between the control voltage and the achieved sealing force based on several sealing processes at different pressures.

When the HSG-C is delivered, the force display is calibrated to the actual sealing force using a calibrated load cell. Over a longer operating period, the transmission of force changes due to wear and increasing friction.

To maintain an accurate sealing force setting, the force display should be checked at regular intervals (approximately every 6 to 12 months) and re-adjusted if necessary, using this load cell or the load cell from the calibrated HSG-P test equipment monitoring device.

Matching Devices

  • Heat-Sealing Machine HSG-CC
  • Calibration System HSG-P